top of page

B-THERMIQ® ROOF is an advanced thermal regulating coating designed for use on pitched and flat roofs . It effectively reduces surface heat gain, protecting the building from excessive heat in summer and heat loss in winter. 

BENEFITS:

✔  Reduces wall heat gain in summer  – reflects up to 94% of solar radiation, preventing the building from overheating. 
✔  Minimizes heat loss in winter  – retains heat inside, reducing heating costs. 
✔  Lower energy bills  – reduces the need for air conditioning and heating. 
✔  Weather resistance  – protection against UV radiation, rain, wind, and pollution. 
✔  Self-cleaning properties  – reduces dust and dirt buildup, reducing the need for frequent cleaning. 
✔  Durability and aesthetics  – long-lasting coating, resistant to fading.

SYSTEM FEATURES

Thermo-Reflective Shield Ultra-Thin Coating Micro Footprint Nanotech Elastomer-Formula Crack Resistant Vapour Permeability Mould Resistant Fungal/Algae Resistant Lichen Resistant Non-Toxic Asbestos Free Sulphur Resistant Anti Corrosive High PH Acoustic Suppression No Thermal Bridges Superior Adhesion Bio-Degradable Breathable No Heavy Metals Non-Flammable

Product Application

B-THERMIQ® ROOF coating is intended for decorative and protective application on roof surfaces made from various materials, in particular galvanized and/or aluminium sheets, roofing felt, and ceramic tiles. Greatly reduces the temperature of the surface, thanks to the light-trapping microspheres. It also improves the heat balance of the building, reflecting the radiation from the protected surface. 

EXCEPTIONAL FINISH: Premixed coating that can be coloured. The structure allows it to have an exceptional  aesthetic finish. Creates a very flexible coating that corrects minor microcracks and does not allow new ones to form.

​​

Performance Parameters: 

- Environmentally and ecologically friendly coating
- Easy to apply, good coverage

- Spreads well on properly prepared substrates
- Forms coatings that improve the building's energy performance; the coating demonstrates 92% reflectance in the visible light spectrum 
- The protective coatings increase the resistance of the finished roofing to environmental loads, including mechanical loads (resistance to cracking and scratching)
- The coatings show high resistance to water absorption during rainfall
- Coatings have enhanced microbiological resistance and are more resistant to soiling. 

Application

Thoroughly mix the B-THERMIQ® ROOF coating before use. A two-coat application is recommended to achieve a final coating thickness of 1mm. Apply the second coat 2-3 hours after the first one, once it is completely dry. Application should be carried out at an ambient temperature ideally between +1S5°C and +25°C. After completing the work, clean all tools with water, following the equipment manufacturer's instructions. 

Concept Models

Industrial and warehouse buildings / Facades of residential, office and commercial buildings / Modular and container construction / Public facilities (hospitals, schools, offices) / Renovation of facades of older buildings / Lightweight buildings where minimum insulation thickness is important / Buildings exposed to intense solar radiation , where the priority is to reduce façade overheating

B-ThermIQ - Pottle
Roof - Roofing Image

 

B-THERMIQ® ULTRA-THIN THERMAL COATING

 

  • Energy Efficiency: Reduced heating and cooling costs, saving money over time. 

  • Temperature Regulation: Maintaining a comfortable interior temperature, regardless of external conditions. 

  • Noise Reduction: Acoustic regulation helps dampen noise, creating peaceful environment inside dwellings. 

  • Condensation Prevention: Proper protection helps reduce condensation, which can damage the structure. 

 

B-THERMIQ® System:

Total Solar Reflectance (TSR) is measured at 93%.

Solar Reflectance Index (SRI) reaches 118%, exceeding conventional cool roof materials.

Emissivity (ε) is high at 0.86, allowing surfaces to release absorbed temperatures effectively.

B-THERMIQ® products create a thermal shield that reflects heat and radiation. This shield is formed by vacuum microspheres tailored to the dimensions of thermal radiation wavelengths, acting like a labyrinth of mirrors.

With the highest TSR (Total Solar Reflectance) on the market, reflecting 93% of thermal energy and featuring high emissivity, as the radiation beam attempting to pass through it is reflected multiple times and redirected back, with virtually no energy absorption.

Key:

*TSR:         Total Solar Reflectance = Accounts for the entire reflected solar spectrum, which includes infrared (IR) heat and visible light (High % is better)

*SRI:           Solar Reflectance Index = Indicates the ability of a materials capacity to return solar energy to the atmosphere, combine light & heat readings (High % is better)

*ε:               Thermal Emissivity = Allows surfaces to release absorbed energy as heat effectively (0-100 - High is better) 

*R-Value:   Mathematical Equivalent = Measures thermal resistance - slowing the cold or heat flow (High values are better)

Minor Dwelling - Banner Molecule Image

Say goodbye to unnecessary expenses and losses immediately

Protect your building with effective, ultra-thin thermal regulation - B-THERMIQ® .
You’ll start saving on heating and cooling costs, effective immediately .

Poor temperature regulation = Huge bills to pay

When heat literally escapes through your walls, and moisture and mould appear on them, you lose your money. Repair bills can cost a fortune. B-THERMIQ® is the best practice alternative.
bottom of page